edge® Multiparameter EC/TDS/Salinity Meter - HI2030

More Views

edge® Multiparameter EC/TDS/Salinity Meter - HI2030

$1,187.73
OR

Availability: Please note - All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please contact us today.

Hanna Instruments is proud to introduce the world’s most innovative EC meter: edge®.


edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.


edge screen size


Large Easy to Read LCD


edge features a 5.5” LCD display that you can clearly view from over 5 meters. The large display and it’s wide 150° viewing angle provide one of the easiest to read LCD’s in the industry.


Capacitive Touch


Capacitive Touch


edge features a capacitive touch keypad that gives a distinctive, modern look. Since the keypad is part of the screen, your buttons can never get clogged with sample residue. The up and down keys move faster when continuously held (ideal for scrolling through numerous logs).


Clear Full Text Readout


Clear Full Text Readout


edge features clear, full text guides displayed on the bottom of the screen. There is no need to decipher scrambled abbreviations or symbols; these helpful messages guide you through every process quickly and easily.

Details

In Cradle

edge® is packed with many cutting edge features to ensure accuracy and usability.

Digital Electrodes

Digital Electrodes

edge electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.

Digital Electrodes

Four Ring Probe

The HI2030 edge EC/TDS/Salinity meter is supplied with the HI763100 four ring platinum conductivity probe that has a built in temperature sensor for automatic temperature compensated measurements. The four ring technology allows for a wide range of measurement with a single probe as compared to amperometric two pole probes that have a limited range and can suffer from polarization effects. The HI763100 probe has a glass and PVDF body with a PEI (polyetherimide ) sleeve. Both materials have excellent resistance against many aggressive chemicals.

3.5mm Probe Input

3.5 mm Probe Input

Plugging an electrode in has never been simpler, no alignments, no broken pins, just connect the 3.5 mm plug and get started.

 

Mounted

edge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.

wall mount

Wall Mount

Using the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built in connector to power edge and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.

Cradle

Cradle and Electrode Holder

edge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimium viewing angle.

sides

edge® is incredibly thin and weighs only 8.8 oz., has an 8 hour battery life, and dual USB inputs.

usb

Two USB Ports

edge includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.

data logging

Data Logging

edge allows you to store up to 1000 log records of data. Data can be logged on demand (200 records), on stability (200 records), or at a predefined interval (600 records). The information stored include current reading,date, time and GLP data.

basic mode

Basic Mode

edge offers both Basic and Standard Modes. In Basic Mode the edge as an EC meter reduces features to simplify operation. In Basic Mode the meter will only allow for automatic temperature compensation, auto ranging of readings, and automatic cell factor correction while calibrating. The temperature correction coefficient is fixed to 1.9% / oC and interval logging is not available. In Standard mode the user has options to change these features.

Video


General

Weight 250 g (8.82 oz)

pH

pH Range -2.00 to 16.00 pH, -2.000 to 16.000 pH*
pH Resolution 0.01 pH, 0.001 pH*
pH Accuracy ±0.01pH, ±0.002 pH*
pH Calibration Automatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers*
pH Temperature Compensation Automatic -5 to 100º C (23 to 212º F) (using integral temperature sensor)

EC/TDS

EC Range 0.00 to 29.99 μS/cm, 3.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm, absolute conductivity ‡
EC Resolution 0.01 μS/cm, 00.1 μS/cm, 0.01 μS/cm, 0.01 mS/cm, 00.1 mS/cm
EC Accuracy ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration 1 Cell Factor calibration; 6 standards available: 84, 1413 μS/cm, 5.00, 12.88, 80.0, 111.8 mS/cm, 1 point offset: 0.00 μS/cm
TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor)
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
EC/TDS Temperature Compensation Automatic -5 to 100 ºC (23 to 212 ºF); NoTC - can be selected to measure absolute conductivity.
Temperature Correction Coefficient 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC
EC to TDS Conversion Factor 0.40 to 0.80 (default value is 0.50)

Salinity, Seawater

Salinity (% NaCl) Range 0.0 to 400.0% NaCl *
Salinity (% NaCl) Resolution 0.1% NaCl
Salinity (% NaCl) Accuracy ±1% of reading
Salinity (% NaCl) Calibration Single point with HI 7037L Standard
Salinity (PSU) Range 2.00 to 42.00 PSU *
Salinity (PSU) Resolution 0.01 PSU,
Salinity (PSU) Accuracy ±1% of reading
Salinity (g/L) Range 0.0 to 80.0 g/L *
Salinity (g/L) Resolution 0.01 g/L
Salinity (g/L) Accuracy ±1% of reading

Oxygen, Dissolved

Oxygen, Dissolved Measurement Type polarographic
Oxygen, Dissolved Range 0.00 to 45.00 ppm (mg/L), 0.0 to 300.0%
Oxygen, Dissolved Resolution 0.01 ppm (mg/L), 0.1%
Oxygen, Dissolved Accuracy ±1.5% of reading
Oxygen, Dissolved Calibration One or two points at 0% (HI 7040) and 100% (water saturated air)
Oxygen, Dissolved Temperature Compensation 0.0 to 50.0 ºC (32.0 to 122 ºF)
Salinity Compensation 0 to 40 g/L 1 g/L
Altitude Compensation -500 to 4,000 m (-1640 to 13120’) 100 m (328’)

Meter Temperature

Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±1.0 °F

General Meter

EC/TDS Probe HI 763100 EC/temperature probe
Logging Type Manual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot
Logging Memory Up to 1000 records
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
GLP yes
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)
Ordering Information HI2030 EC kit includes: HI763100 Conductivity probe, 3 sachets of 1413 μS/cm conductivity standard, 3 sachets of 12.88 mS/cm conductivity standard, USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, instruction manual and Quality certificate.
Notes * temperature limits will be reduced to actual probe/sensor limits
** with temperature compensation function disabled
*** For standard mode only (logging)

SDS: