Burettes and Dosing System
Exchangeable Burette System
With Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents, preventing cross-contamination and saving time.
Multiple Burette Sizes
The HI901C comes standard with a 25 mL burette but may be equipped with a 5 mL, 10 mL, or 50 mL burette. Each burette is constructed with a ground glass syringe and chemically resistant PTFE plunger.
Linear and Dynamic Dosing
Precision Dosing Pump
Our unmatched 40,000-step piston-driven pump is capable of dosing extremely small and precise volumes of titrant or reagent.
Chemically Resistant Tubing
Aspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light-sensitive reagents.
Titration Capabilities
Dynamic Titrant Dosing
The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.
Signal Stability Timing
The signal stability feature monitors when the mV response of the titration reaction stabilizes before providing the next titrant dose. This ensures reliable measurement values throughout the length of a titration.
Equivalence Endpoint Detection
Equivalence endpoint detection is critical in applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.
Multiple Titration Types
Paired with the right electrode from our sensor line, our potentiometric titrator can perform acid/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and titrations with an ion-selective electrode.
Interface and Display
Detailed Titration Graphs
A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.
Interactive Color Display
A large, color LCD screen clearly shows the chosen titration method along with results, units, titration volume, temperature, and mV or pH values. The HI901C also offers multilanguage support.
Simple and Quick Navigation
Virtual key selections present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information.
Data and Storage
Customizable Titration Reports
Each titration report is fully customizable so users can ensure they are storing and filing the appropriate data required for their application and procedures.
Flexible GLP Management
All necessary GLP (Good Laboratory Practice) information can be recorded with each sample including sample identification, company and operator name, date, time, electrode ID codes, and calibration information.
Effortless Data Transfer
Data can easily be transferred to a USB flash drive or PC with the Hanna HI900PC application software. The USB port allows for the transfer of titration methods, titration reports, and software upgrades via a USB flash drive.
Methods of Analysis
Customizable Methods
The HI901C can store up to 100 user-defined or standard titration methods. Each method may be customized and optimized for performance based on application and user requirements.
Titration Method Support
Onsite installation, training, and customization is available from one of our Applications or Service experts. Hanna offers continued support via phone or webinar for any questions you might have along the way.
Market-Specific Methods Packs
Hanna offers titration method packages for various markets including food, beverage, dairy, wine, and more. Ask our Sales Consultants about which methods in our library are available for your specific needs.
Adaptable Standard Methods
Our technical experts can program and customize standard methods developed by such affiliations as ISO, ASTM, AOAC, AOCS, EPA, and more directly onto your titrator. Ask our Sales Consultants which standard methods are possible with our HI901C system.
Connectivity and Functionality
Multifunctional with Four Working Modes
The HI901C functions as a titrator, pH meter, mV/ORP meter, and ISE meter. Valuable laboratory bench space is saved, and multiple analyses can be performed on one sample.
Multiple Connections
The titrator offers device support for two burettes and two analog boards, which allows two electrodes and two stirrers to be simultaneously connected to one unit (HI901C2-02 only).
Multiple Peripherals
Users can print reports directly from the titrator using a standard parallel printer. An external monitor and keyboard may be attached for added versatility, as well as an analytical balance for automatic sample mass entry for titrations.
Versatile Data Management
- HI901C titration system can be easily incorporated into any existing GLP data management program: Easily record all necessary GLP information with every sample, such as sample identification, company and operator name, date, time, electrode ID codes, and calibration information.
- Data can be transferred to a PC using Hanna HI900PC software
- The USB port allows for the easy transfer of methods, reports, and software upgrades via a USB flash drive
- Users can print reports of analyses directly from the titrator using a standard parallel printer
- An external monitor and keyboard can be attached for added versatility