Hanna Instruments Australia
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm
Hanna Instruments Australia
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm

Automatic Titration System - HI901C1

$6,583.50


Prices include GST. Not all items are in stock. Call 03 9769 0666 to confirm.

The HI901C1 automatic titrator complements our wide range of products dedicated to efficient and accurate laboratory analysis. The HI901C potentiometric titrator can perform acid/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and ion selective titrations. This powerful titrator dispenses the titrant, detects the endpoint, and performs all necessary calculations and graphing automatically. In addition to titration mode, the HI901C also operates as a fully functional pH, mV/ORP, and ion selective electrode (ISE) meter. This titrator is supplied with a pack of standard methods or you can create your own. Methods (standard or user) can be easily transferred between titrators via USB flash drive or PC application.

Burettes and Dosing System

Exchangeable Burette System
With Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents, preventing cross-contamination and saving time.

Multiple Burette Sizes
The HI901C comes standard with a 25 mL burette but may be equipped with a 5 mL, 10 mL, or 50 mL burette. Each burette is constructed with a ground glass syringe and chemically resistant PTFE plunger.

Linear and Dynamic Dosing

Precision Dosing Pump
Our unmatched 40,000-step piston-driven pump is capable of dosing extremely small and precise volumes of titrant or reagent.

Chemically Resistant Tubing
Aspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light-sensitive reagents.

Titration Capabilities

Dynamic Titrant Dosing
The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.

Signal Stability Timing
The signal stability feature monitors when the mV response of the titration reaction stabilizes before providing the next titrant dose. This ensures reliable measurement values throughout the length of a titration.

Equivalence Endpoint Detection
Equivalence endpoint detection is critical in applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.

Multiple Titration Types
Paired with the right electrode from our sensor line, our potentiometric titrator can perform acid/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and titrations with an ion-selective electrode.

Interface and Display

Detailed Titration Graphs
A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.

Interactive Color Display
A large, color LCD screen clearly shows the chosen titration method along with results, units, titration volume, temperature, and mV or pH values. The HI901C also offers multilanguage support.

Simple and Quick Navigation
Virtual key selections present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information.

Data and Storage

Customizable Titration Reports
Each titration report is fully customizable so users can ensure they are storing and filing the appropriate data required for their application and procedures.

Flexible GLP Management
All necessary GLP (Good Laboratory Practice) information can be recorded with each sample including sample identification, company and operator name, date, time, electrode ID codes, and calibration information.

Effortless Data Transfer
Data can easily be transferred to a USB flash drive or PC with the Hanna HI900PC application software. The USB port allows for the transfer of titration methods, titration reports, and software upgrades via a USB flash drive.

Methods of Analysis

Customizable Methods
The HI901C can store up to 100 user-defined or standard titration methods. Each method may be customized and optimized for performance based on application and user requirements.

Titration Method Support
Onsite installation, training, and customization is available from one of our Applications or Service experts. Hanna offers continued support via phone or webinar for any questions you might have along the way.

Market-Specific Methods Packs
Hanna offers titration method packages for various markets including food, beverage, dairy, wine, and more. Ask our Sales Consultants about which methods in our library are available for your specific needs.

Adaptable Standard Methods
Our technical experts can program and customize standard methods developed by such affiliations as ISO, ASTM, AOAC, AOCS, EPA, and more directly onto your titrator. Ask our Sales Consultants which standard methods are possible with our HI901C system.

Connectivity and Functionality

Multifunctional with Four Working Modes
The HI901C functions as a titrator, pH meter, mV/ORP meter, and ISE meter. Valuable laboratory bench space is saved, and multiple analyses can be performed on one sample.

Multiple Connections
The titrator offers device support for two burettes and two analog boards, which allows two electrodes and two stirrers to be simultaneously connected to one unit (HI901C2-02 only).

Multiple Peripherals
Users can print reports directly from the titrator using a standard parallel printer. An external monitor and keyboard may be attached for added versatility, as well as an analytical balance for automatic sample mass entry for titrations.

Versatile Data Management

  1. HI901C titration system can be easily incorporated into any existing GLP data management program: Easily record all necessary GLP information with every sample, such as sample identification, company and operator name, date, time, electrode ID codes, and calibration information.
  2. Data can be transferred to a PC using Hanna HI900PC software
  3. The USB port allows for the easy transfer of methods, reports, and software upgrades via a USB flash drive
  4. Users can print reports of analyses directly from the titrator using a standard parallel printer
  5. An external monitor and keyboard can be attached for added versatility

Specifications

pH    
 Range   -2.0 to 20.0; -2.00 to 20.00 ; -2.000 to 20.000
 Resolution   0.1; 0.01; 0.001 pH
 Accuracy (@25°C/77°F)   ±0.1 mV
 Calibration   Up to five-point calibration, eight standard buffers and five custom buffers
mV    
 Range   mV -2000.0 to 2000.0
 Resolution   0.1 mV
 Accuracy (@25°C)   ±0.1mV
 mV Calibration   Single Point Offset
ISE    
 Range   1 x 10-6 to 9.99 x 1010
 Resolution   1, 0.1, 0.01
 Accuracy   ±0.5% monovalent; ±1% divalent
 Calibration   Up to five-point calibration, seven standard solutions and five user-defined standards
Temperature    
 Range   -20.0 to 120.0°C
 Resolution   0.1°C/0.1°F/0.1K
 Accuracy   ±0.1°C; ±0.2°F/±0.1K (excluding probe error)
Analog Board(s)   Each analog board provides: BNC (pH/mV/ISE) Input (1), reference input (1), Temperature input (1), Stirrer input (1)
Analog board capability   1
Dosing pump capabilities   2
Burette included   1 (25ml)
Burette Sizes   5, 10, 25 and 50 mL
Burette Resolution   1/40000
Display Resolution   0.001 mL
Dosing Accuracy   ±0.1% of full burette volume
Display   5.7” (320 x 240 pixel) backlit colour LCD
Languages   English, Portuguese, Spanish
Methods   load up to 100 methods (standard and user-defined)
Burette Auto-Detection   burette size is automatically recognised when inserted into the pump unit
Programmable Stirrer   overhead propeller type, 200-2500 RPM, resolution 100 rpm
Flow Rate   user-selectable from 0.1 mL/min to 2 x burette volumes/min
Temperature Compensation   manual or automatic (ATC)
End-point Determination   equivalence point (1st or 2nd derivative) or fixed pH/mV value
Potentiometric Titrations   acid-base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, argentometric
Measurement Units   user specified expression of concentration units to suit specific calculation requirements
Real Time & Stored Graphs   mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve, in pH-mode, mV-mode or ISE mode; pH/mV/concentration values versus time
Data Storage   up to 100 titration and pH/mV/ISE reports
USB Host (Side)   flash drive compatibility for transfers of methods and reports
Peripherals (Rear)   connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232
GLP Conformity   instrumentation data storage and printing capabilities
Operating Environment   10 to 40°C (50 to 104°F), up to 95% RH
Storage Environment   -20 to 70°C (-4 to 158°F), up to 95% RH
Power   “-02” models: 230VAC
Dimensions   390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)
Weight   approximately 9 kg (20 lbs.) with one pump, stirrer & sensors

Manuals

Ordering info

HI901C1-02 supplied with:

  • Titrator with one analog board
  • Overhead propeller stirrer with stand
  • 25 mL glass burette
  • Dosing pump drive
  • Temperature sensor
  • USB cable
  • 256 Mb USB flash drive and PC software

Purchase & Shipping

All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please send an email to sales@hannainst.com.au or call us on (03) 9769 0666.

Free standard delivery: We offer free delivery within Australia on orders over $150, typically arriving within 5 to 7 days. Delivery times may vary depending on the courier service and the recipient's location. Free shipping is not available with other offers or discounts.

Same-day despatch: Place your order before 1 PM Monday to Friday for same-day despatch (leaves our warehouse). Delivery times may vary depending on the courier service and the recipient's location. Subject to stock availability.

Please note that we do not offer shipping to PO Box addresses.

Additional information

Weight 9 kg
Dimensions 390 × 350 × 380 cm