Chat with us, powered by LiveChat

Benchtop Multiparameter Photometer for Water Analysis - HI83200

More Views

Benchtop Multiparameter Photometer for Water Analysis - HI83200

$1,980.00
OR

Availability: Please note - All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please contact us today.

The HI83200 Multiparameter Photometer for specific ion measurements combines accuracy and ease of use in an ergonomic benchtop design. This meter is one of the most versatile photometers in the market, offering 44 measurement methods using ready-made liquid or powder reagents. The HI83200 has many advanced features including a graphic LCD to display various chemical forms and a step by step tutorial mode for inexperienced users.


parameters measured


44 measurement methods


USB


USB for data export


timer


Built-in timer for measurement consistency and accuracy


view compatible reagents

Details

From aluminum to zinc, the HI83200 benchtop photometer offers 44 measurement methods for different key water quality parameters. This photometer features an advanced optical system that uses special tungsten lamps, narrow band interference filters, and silicon photodetectors to ensure accurate photometric readings every time. As a benchtop meter, the HI83200 operates on 12VDC supplied from an AC adapter. When portability is desired the meter can also operate on the internal rechargeable battery. The HI83200 uses a graphic backlit LCD that allows for an intuitive user interface. The meter offers a tutorial mode that gives a step-by-step procedure for performing a measurement. The result obtained can be displayed in various chemical forms based on the user’s preference. For tracking of data, results can be logged and then exported to a Windows® compatible PC using the HI92000 software and HI920013 USB cable.

 

Features at-a-glance

Backlit Graphic LCD Display - The HI83200 features a backlit graphic display with virtual keys and on-screen help to provide for an intuitive user interface.

Data Logging - Users can store up to 200 readings by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button.

PC Connectivity - Logged readings can be quickly and easily transferred to a PC via USB using the HI92000 Windows®compatible software.

Result Conversion - Eliminates confusion by automatically converting readings to other chemical forms. Common conversions are available at the touch of a button.

On-screen Tutorial - With the tutorial function enabled, short guides relating to the current operation are displayed. At any stage in the setup or measurement process, the dedicated HELP button is also available to show contextual help.

Auto-shut off - Automatic shut off after 10 minutes of non-use when the meter is in measurement mode and operating on the internal rechargeable battery.  

Battery Status Indicator - Indicates the amount of battery life left.

Built-in Timer - Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed.

Error Messages - Messages on display alerting to problems including no cap, high zero, and standard too low.

Cuvette Cover - Aids in stopping stray light from affecting measurements.

Cooling Lamp Indicator - To maintain the desirable wavelength to be used for absorbance, it is necessary to ensure components are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken.

Units of Measure - Appropriate unit of measure is displayed along with reading.


On-screen Features

multiparameter photometer method

Method Selection
Users can easily select any one of the 44 measurement methods via the dedicated METHOD button.

multiparameter logging

Data Logging
Up to 200 measurement readings can be logged and recalled for future use.

multiparameter logging recall

Log Recall
Logged data can easily be recalled and the chemical form can be converted at the touch of a button.

 
 


Advanced Optical System

The HI83200 features 44 different methods that can be measured using ready-made liquid or powder reagents. When the appropriate reagent is used for a selected method, the reaction between the reagent and the sample causes a color change; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. A narrow band interference filter allows the relevant wavelength of light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

photometer multiparameter optical





Parameters

Reagents are available in liquid or powder form, and the amount of each reagent is precisely dosed to ensure maximum repeatability.


Parameter

Range

Resolution

Accuracy

Method

Reagent Code

Alkalinity

0 to 500 mg/L (ppm) as CaCO3

5 mg/L

±5 mg/L ±10% of reading

bromocresol green

HI93755-01

Aluminum

0.00 to 1.00 mg/L (ppm)

0.01 mg/L

±0.02 mg/L ±4% of reading

aluminon

HI93712-01

Ammonia MR

0.00 to 10.00 mg/L (ppm)

0.01 mg/L

±0.05 mg/L ±5% of reading

Nessler

HI93715-01

Ammonia LR

0.00 to 3.00 mg/L (ppm)

0.01 mg/L

±0.04 mg/L ±4% of reading

Nessler

HI93700-01

Bromine

0.00 to 8.00 mg/L (ppm)

0.01 mg/L

±0.08 mg/L ±3% of reading

DPD

HI93716-01

Calcium

0 to 400 mg/L (ppm)

10 mg/L

±10 mg/L ±5% of reading

oxalate

HI937521-01**

Chlorine Dioxide

0.00 to 2.00 mg/L (ppm)

0.01 mg/L

±0.10 mg/L ±5% of reading

chlorophenol red

HI93738-01

Chlorine, Free

0.00 to 2.50 mg/L (ppm)

0.01 mg/L

±0.03 mg/L ±3% of reading

DPD

HI93701-01

Chlorine, Total

0.00 to 3.50 mg/L (ppm)

0.01 mg/L

±0.03 mg/L ±3% of reading

DPD

HI93711-01

Chromium VI HR

0 to 1000 μg/L

1  μg/L

±5  μg/L ±4% of reading

diphenylcarbohydrazide

HI93723-01

Chromium VI LR

0 to 300 μg/L

1 μg/L

±1 μg/L ±4% of reading

diphenylcarbohydrazide

HI93749-01

Color of Water

0 to 500 PCU

1 PCU

±10 PCU ±5% of reading

colorimetric platinum cobalt

--

Copper HR

0.00 to 5.00 mg/L (ppm)

0.01 mg/L

±0.02 mg/L ±4% of reading

bicinchoninate

HI93702-01

Copper LR

0 to 1000 μg/L

1 μg/L

±10 μg/L ±5% of reading

bicinchoninate

HI95747-01

Cyanuric Acid

0 to 80 mg/L (ppm)

1 mg/L

±1 mg/L ±15% of reading

turbidimetric

HI93722-01

Fluoride

0.00 to 2.00 mg/L (ppm)

0.01 mg/L

±0.03 mg/L ±3% of reading

SPADNS

HI93729-01

Hardness, Calcium

0.00 to 2.70 mg/L (ppm) (as CaCO3)

0.01 mg/L

±0.11 mg/L ±5% of reading

calmagite

HI93720-01

Hardness, Magnesium

0.00 to 2.00 mg/L (ppm) (as CaCO3)

0.01 mg/L

±0.11 mg/L ±5% of reading

EDTA colorimetric

HI93719-01

Hydrazine

0 to 400 μg/L

1 μg/L

±4% of full scale reading

p-Dimethylaminobenzaldehyde

HI93704-01

Iodine

0.0 to 12.5 mg/L (ppm)

0.1 mg/L

±0.1 mg/L ±5% of reading

DPD

HI93718-01

Iron HR

0.00 to 5.00 mg/L (ppm)

0.01 mg/L

±0.04 mg/L ±2% of reading

phenanthroline

HI93721-01

Iron LR

0 to 400 μg/L

1 μg/L

±10 μg/L ±8% of reading

TPTZ

HI93746-01**

Magnesium

0 to 150 mg/L (ppm)

5 mg/L

±5 mg/L ±3% of reading

calmagite

HI937520-01**

Manganese HR

0.0 to 20.0 mg/L (ppm)

0.1 mg/L

±0.2 mg/L ±3% of reading

periodate

HI93709-01

Manganese LR

0 to 300 μg/L

1 μg/L

±10 μg/L ±3% of reading

PAN

HI93748-01**

Molybdenum

0.0 to 40.0 mg/L (ppm)

0.1 mg/L

±0.3 mg/L ±5% of reading

mercaptoacetic acid

HI93730-01

Nickel HR

0.00 to 7.00 g/L (ppt)

0.01 g/L

±0.07 g/L ±4% of reading

photometric

HI93726-01

Nickel LR

0.000 to 1.000 mg/L (ppm)

0.001 mg/L

±0.010 mg/L ±7% of reading

PAN

HI93740-01**

Nitrate

0.0 to 30.0 mg/L (ppm)

0.1 mg/L

±0.5 mg/L ±10% of reading

cadmium reduction

HI93728-01

Nitrite HR

0 to 150 mg/L (ppm)

1 mg/L

±4 mg/L ±4% of reading

ferrous sulfate

HI93708-01

Nitrite LR

0 .00 to 1.15 mg/L (ppm)

0.01 mg/L

±0.06 mg/L ±4% of reading

diazotization

HI93707-01

Oxygen, Dissolved (DO)

0.0 to 10.0 mg/L (ppm)

0.1 mg/L

±0.4 mg/L ±3% of reading

Winkler

HI93732-01

Ozone

0.00 to 2.00 mg/L (ppm)

0.01 mg/L

±0.02 mg/L ±3% of reading

DPD

HI93757-01

pH

6.5 to 8.5 pH

0.1 pH

±0.1 pH

phenol red

HI93710-01

Phosphate HR

0.0 to 30.0 mg/L (ppm)

0.1 mg/L

±1 mg/L ±4% of reading

amino acid

HI93717-01

Phosphate LR

0.00 to 2.50 mg/L (ppm)

0.01 mg/L

±0.04 mg/L ±4% of reading

ascorbic acid

HI93713-01

Phosphorus

0.0 to 15.0 mg/L (ppm)

0.1 mg/L

±0.3 mg/L ±4% of reading

amino acid

HI93706-01

Potassium HR

20 to 200 mg/L (ppm)

5 mg/L

±30 mg/L ±7% of reading

turbidimetric tetraphenylborate

HI93750-01

Potassium MR

10 to 100 mg/L (ppm)

2.5 mg/L

±15 mg/L ±7% of reading

turbidimetric tetraphenylborate

HI93750-01

Potassium LR

0.0 to 20.0 mg/L (ppm)

0.5 mg/L

±3.0 mg/L ±7% of reading

turbidimetric tetraphenylborate

HI93750-01

Silica

0.00 to 2.00 mg/L (ppm)

0.01 mg/L

±0.03 mg/L ±3% of reading

heteropoly blue

HI93705-01

Silver

0.000 to 1.000 mg/L (ppm)

0.005 mg/L

±0.020 mg/L ±5% of reading

PAN

HI93737-01**

Sulfate

0 to 100 mg/L (ppm)

5 mg/L

±5 mg/L ±3% of reading

turbidimetric

HI93751-01

Zinc

0.00 to 3.00 mg/L (ppm)

0.01 mg/L

±0.03 mg/L ±3% of reading

zincon

HI93731-01

**  Reagents for 50 tests. †  Unless noted otherwise, all reagent codes ending with -01 are for 100 tests.

pH

pH Range 6.5 to 8.5 pH
pH Resolution 0.1 pH
pH Accuracy ±0.1 pH
pH Method phenol red

Oxygen, Dissolved

Oxygen, Dissolved Range 0.0 to 10.0 mg/L (as O2)
Oxygen, Dissolved Resolution 0.1 mg/L
Oxygen, Dissolved Accuracy ±0.4 mg/L ±3% of reading
Oxygen, Dissolved Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method

Alkalinity

Alkalinity Range 0 to 500 mg/L as CaCO3
Alkalinity Resolution 5 mg/L
Alkalinity Accuracy ±5 mg/L ±10% of reading
Alkalinity Method Colorimetric Method

Aluminum

Aluminum Range 0.00 to 1.00 mg/L
Aluminum Resolution 0.01 mg/L
Aluminum Accuracy ±0.02 mg/L ±4%
Aluminum Method Adaptation of the aluminon method

Ammonia

Ammonia Range Low Range: 0.00 to 3.00 mg/L (as NH3-N)
Medium Range: 0.00 to 10.00 mg/L (as NH3-N)
Ammonia Resolution 0.01 mg/L
Ammonia Accuracy Low Range: ±0.04 mg/L ±4% of reading
Medium Range: ±0.05 mg/L ±5% of reading
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method.

Bromine

Bromine Range 0.00 to 8.00 mg/L (as Br2)
Bromine Resolution 0.01 mg/L
Bromine Accuracy ±0.08 mg/L ±3% of reading
Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.

Calcium

Calcium Range 0 to 400 mg/L
Calcium Resolution 10 mg/L
Calcium Accuracy ±10 mg/L ±5% of reading at 25 °C
Calcium Method Adaptation of the Oxalate method.

Chlorine Dioxide

Chlorine Dioxide Range 0.00 to 2.00 mg/L
Chlorine Dioxide Resolution 0.01 mg/L
Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading at 25 °C
Chlorine Dioxide Method Adaptation of the Chlorophenol Red method.

Chlorine

Free Chlorine Range 0.00 to 2.50 mg/L
Free Chlorine Resolution 0.01 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading
Total Chlorine Range 0.00 to 3.50 mg/L
Total Chlorine Resolution 0.01 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading
Chlorine Method Adaptation of the EPA DPD method 330.5.

Chromium, Hexavalent

Chromium, Hexavalent Range Low Range: 0 to 300 μg/L (as Cr6+)
High Range: 0 to 1000 μg/L (as Cr6+)
Chromium, Hexavalent Resolution 1 μg/L
Chromium, Hexavalent Accuracy Low Range: ±1 μg/L ±4% of reading
High Range: ±5 μg/L ±4% of reading
Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.

Color, Water

Color, Water Range 0 to 500 PCU (Platinum Cobalt Units)
Color, Water Resolution 1 PCU
Color, Water Accuracy ±10 PCU ±5% of reading
Color, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.

Copper

Copper Range Low Range: 0 to 1000 μg/L
High Range: 0.00 to 5.00 mg/L
Copper Resolution Low Range: 1 μg/L
High Range: 0.01 mg/L
Copper Accuracy Low Range: ±10 μg/L ±5% of reading
High Range: ±0.02 mg/L ±4% of reading
Copper Method Adaptation of the EPA method.

Cyanuric Acid

Cyanuric Acid Range 0 to 80 mg/L
Cyanuric Acid Resolution 1 mg/L
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading
Cyanuric Acid Method Adaptation of the turbidimetric method

Fluoride

Fluoride Range 0.00 to 2.00 mg/L
Fluoride Resolution 0.01 mg/L
Fluoride Accuracy ±0.03 mg/L ±3% of reading
Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method.

Hardness, Calcium

Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3)
Hardness, Calcium Resolution 0.01 mg/L
Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method

Hardness, Magnesium

Hardness, Magnesium Range 0.00 to 2.00 mg/L (as CaCO3)
Hardness, Magnesium Resolution 0.01 mg/L
Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method

Hydrazine

Hydrazine Range 0 to 400 μg/L
Hydrazine Resolution 1 μg/L
Hydrazine Accuracy ±4% of full scale reading
Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method

Iodine

Iodine Range 0.0 to 12.5 mg/L
Iodine Resolution 0.1 mg/L
Iodine Accuracy ±0.1 mg/L ±5% of reading
Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method

Iron

Iron Range Low Range: 0 to 400 μg/L
High Range: 0.00 to 5.00 mg/L
Iron Resolution Low Range: 1 μg/L
High Range: 0.01 mg/L
Iron Accuracy Low Range: ±10 μg/L ±8% of reading
High Range: ±0.04 mg/L ±2% of reading
Iron Method Low Range: Adaptation of the TPTZ Method.
High Range: Adaptation of the EPA Phenantroline method 315B, for natural and treated waters.

Magnesium

Magnesium Range 0 to 150 mg/L
Magnesium Resolution 5 mg/L
Magnesium Accuracy ±5 mg/L ±3% of reading
Magnesium Method Adaptation of the Calmagite method.

Manganese

Manganese Range Low Range: 0 to 300 μg/L
High Range: 0.0 to 20.0 mg/L
Manganese Resolution Low Range: 1 μg/L
High Range: 0.1 mg/L
Manganese Accuracy Low Range: ±10 μg/L ±3% of reading
High Range: ±0.2 mg/L ±3% of reading
Manganese Method Low Range: Adaptation of the PAN Method
High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method

Molybdenum

Molybdenum Range 0.0 to 40.0 mg/L
Molybdenum Resolution 0.1 mg/L
Molybdenum Accuracy ±0.3 mg/L ±5% of reading
Molybdenum Method Adaptation of the mercaptoacetic acid method.

Nickel

Nickel Range Low Range: 0.000 to 1.000 mg/L
High Range: 0.00 to 7.00 g/L
Nickel Resolution Low Range: 0.001 mg/L
High Range: 0.01 g/L
Nickel Accuracy Low range: ±0.010 mg/L ±7% of reading
High Range: ±0.07 g/L ±4% of reading
Nickel Method Low Range: Adaptation of the PAN method
High Range: Adaptation of the photometric method

Nitrate

Nitrate Range 0.0 to 30.0 mg/L
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Nitrate Method Adaptation of the cadmium reduction method.

Nitrite

Nitrite Range Low Range: 0.00 to 1.15 mg/L
High Range: 0 to 150 mg/L
Nitrite Resolution Low Range: 0.01 mg/L
High Range: 1 mg/L
Nitrite Accuracy Low Range: ±0.06 mg/L ±4% of reading
High Range: ±4 mg/L ±4% of reading
Nitrite Method Low Range: Adaptation of the EPA Diazotization method 354.1.
High Range: Adaptation of the Ferrous Sulfate method.

Ozone

Ozone Range 0.00 to 2.00 mg/L (as O3)
Ozone Resolution 0.01 mg/L
Ozone Accuracy ±0.02 mg/L ±3% of reading
Ozone Method Colorimetric DPD Method

Phosphate

Phosphate Range Low Range: 0.00 to 2.50 mg/L (as PO43-)
High range: 0.0 to 30.0 mg/L (as PO43-)
Phosphate Resolution Low Range: 0.01 mg/L
High Range: 0.1 mg/L
Phosphate Accuracy Low Range: ±0.04 mg/L ±4% of reading
High Range: ±1 mg/L ±4% of reading
Phosphate Method Low Range: Adaptation of the Ascorbic Acid method
High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method

Phosphorous

Phosphorous Range 0.0 to 15.0 mg/L
Phosphorous Resolution 0.1 mg/L
Phosphorous Accuracy ±0.3 mg/L ±4% of reading
Phosphorous Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method.

Potassium

Potassium Range Low Range: 0.0 to 20.0 mg/L
Medium Range: 10 to 100 mg/L
High Range: 20 to 200 mg/L
Potassium Resolution Low Range: 0.5 mg/L
Medium Range: 2.5 mg/L
High Range: 5 mg/L
Potassium Accuracy Low Range: ±3.0 mg/L ±7% of reading
Medium Range: ±15 mg/L ±7% of reading
High Range: ±30 mg/L ±7% of reading
Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method.

Silica

Silica Range 0.00 to 2.00 mg/L
Silica Resolution 0.01 mg/L
Silica Accuracy ±0.03 mg/L ±3% of reading
Silica Method Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Blue method.

Silver

Silver Range 0.000 to 1.000 mg/L
Silver Resolution 0.005 mg/L
Silver Accuracy ±0.020 mg/L ±5% of reading
Silver Method Adaptation of the PAN method.

Sulfate

Sulfate Range 0 to 100 mg/L
Sulfate Resolution 5 mg/L
Sulfate Accuracy ±5 mg/L ±3% of reading
Sulfate Method Sulfate is precipitated with barium chloride crystals. Light absorbance of the suspension is measured.

Zinc

Zinc Range 0.00 to 3.00 mg/L
Zinc Resolution 0.01 mg/L
Zinc Accuracy ±0.03 mg/L ±3% of reading
Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method.

General Meter

Logging Memory 200 samples
Connectivity USB
Display Liquid Crystal Display (LCD)
Battery Type/Life built-in rechargeable battery
Power Supply external 12 VDC power adapter or built-in rechargeable battery
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 235 x 200 x 110 mm (9.2 x 7.87 x 4.33”)
Weight 0.9 kg (2 lbs)
Photometer/Colorimeter Light Source up to 5 tungsten lamps with different narrow band interference filters
Photometer/Colorimeter Light Detector silicon photocell
Ordering Information HI83200 is supplied with sample cuvettes (4) with caps, sample preparation kit, cloth for wiping cuvettes, 60 mL glass bottle for dissolved oxygen analysis, scissors, AC/DC power adapter, and instruction manual.

SDS:

Reviews: