Hanna Instruments Australia
BLACK FRIDAY SALE: 20% OFF sitewide Use code BF24
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm
Hanna Instruments Australia
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm

Autosampler for Potentiometric Titrator - 16 beaker tray - 2 peristaltic pumps - HI922-120

The HI922 Autosampler is an automated titration sample handling system designed for use with the HI932 Automatic Titration System. This high quality system makes the titration of multiple samples quick and easy. The HI922 Autosampler interfaces directly with the HI932 to access titration methods, allowing up to 18 samples to be run consecutively.

The HI922 can utilize up to three peristaltic pumps for reagent addition, sample leveling, and waste aspiration. An included control panel allows for manual operation of the motors and pumps. The Autosampler also features a built-in magnetic stirrer or optional overhead stirrer, status indicator lights, USB interface with compatible barcode reader, and built-in RFID for each tray.

Intuitive Automation

Chemically Resistant Pumps

You can connect up to three peristaltic pumps on the HI922 Autosampler. These peristaltic pumps use high performance plastic, engineered to be chemically resistant with a long service life. Each pump has a flow rate greater than 200 mL/min and can be used for reagent addition, sample leveling, or waste removal.

Multipurpose Arm

The Autosampler’s durable electrode holder is able to accommodate three 12 mm electrodes, a temperature sensor, one aspiration tube, five multipurpose tubes, and an overhead stirring assembly, allowing for maximum versatility. The multipurpose spaces can be utilized for a variety of functions including reagent addition or burette dosing.

Autosampler Status Indicator

Highly visible status lights are located on top of the Autosampler. These lights correspond to the status indication on the HI932 titrator display and can clearly be seen from a distance. These indicator lights double as a safety feature and serve to automatically stop the current titration sequence with a simple press.

Carousel Functionality

Choice of Sample Trays

The HI922 is able to automate samples using a 16 or 18 sample tray. The 16 sample tray accommodates 150 mL beakers while the 18 sample tray holds 100 mL beakers. The trays are composed of chemically resistant material and are easily removable. Each tray is dishwasher safe, providing a quick and simple way for users to clean regularly.

Automatic Tray Recognition

The HI921 sample trays feature a built-in RFID reader that’s able to detect and communicate the size and serial number of any tray on the carousel. Users can set up multiple trays designated to differing sample sets without confusion. The RFID reader will ensure that the appropriate tray is used each time.

Optical IR Beaker Detection

An optical IR beam is able to detect the presence or absence of each beaker within the sample tray. A user can select which action the HI922 should take if a beaker is missing during a titration sequence. The Autosampler may be programmed to skip the missing beaker, pause, or stop the titration sequence.

Smart Positioning

The HI922 contains an absolute encoder that can track the tray position without needing to return “home” or calibrate. The encoder retains the position information when powered off and is readily available when powered back on.

Integrated Magnetic Stirrer

A magnetic stirrer comes built into each carousel assembly. Users simply have to add a small magnetic stir bar to each sample beaker to ensure samples are well-mixed during titrations. An optional overhead propeller stirrer may also be installed as an alternative. The HI921 allows you to easily adjust the stirring speed of both the built-in and overhead stirrers for optimal mixing.

Sample Handling & Recording

Expedited Sample Entry

Sample names can be auto-incremented for speedy and convenient sample sample entry.

Configurable Balance Interface

Sample sizes may be automatically communicated from any laboratory analytical balance with a RS232 serial output, saving time and labor.

Flexible Sample Assignment

Up to 18 samples may be run consecutively with the options to accommodate up to 3 rinse beakers and 1 storage beaker.

Organized Sample Table

A USB-compatible barcode reader may be connected to the Autosampler, associating names with samples for improved recordkeeping.

Titration Data & Reporting

HI932 with HI922 autosampler

Customizable Autosampler Sequences

The HI932 can store up to 100 user-defined or standard titration methods that can be accessed by the Autosampler. Each method may be customized and optimized for sequence performance based on application and user requirements.

Detailed Sequence Reports

Autosampler sequence reports detail sample names, beaker positions, sample sizes, and results for the sample tray in addition to detailed titration reports for individual samples.

Customizable Titration Reports

Each titration report is fully customizable so users can be confident they are storing and filing the appropriate data required for their application and procedures.

Specifications

SKU HI922-120
Name Autosampler for Potentiometric Titrator - HI922-16 beaker tray-2 peristaltic pumps
Weight 20 lbs

Manuals

Purchase & Shipping

All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please send an email to sales@hannainst.com.au or call us on (03) 9769 0666.

Free standard delivery: We offer free delivery within Australia on orders over $150, typically arriving within 5 to 7 days. Delivery times may vary depending on the courier service and the recipient's location. Free shipping is not available with other offers or discounts.

Same-day despatch: Place your order before 1 PM Monday to Friday for same-day despatch (leaves our warehouse). Delivery times may vary depending on the courier service and the recipient's location. Subject to stock availability.

Please note that we do not offer shipping to PO Box addresses.

Additional information

Parameter

Titration