Hanna Instruments Australia
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm
Hanna Instruments Australia
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm

GroLine Monitor for Hydroponic Nutrients - HI981421-Threaded probe for insertion mounting

$947.40

The HI981420 GroLine Monitor for Hydroponic Nutrients provides around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.

 

Quick to setup, simple to use, this monitor was designed with Hydroponics, Aquaponics, and Greenhouses in mind. Make your nutrient solution easy to manage with the GroLine Monitor.

 

Grow better with GroLine.

  • Get 24/7 pH&EC measurements for consistent yields every time.
  • Good Laboratory Practice (GLP) feature for professional accuracy.
  • Calibrate pH and EC with a single Quick Cal solution.

Description

groline monitor display

One quick glance is all it takes.

A large clear LCD displays all of your essential readings so you know what your hydroponic nutrients solution is doing 24/7. High and low alarms flash warning you if something needs adjusting.

groline monitor display

Monitor changes over time.

The GroLine Monitor automatically logs your results every 15 minutes over the last 30 days. Minimum, maximum, and average values are stored so you can recognize when patterns arise and help prevent future problems.

HI1285-5 pH/EC/TDS Multiparameter Probe

One probe. Three measurements.

Our 3-in-1 pre-amplified probe measures pH, EC/TDS, and temperature in a single, durable, polypropylene body making the GroLine Monitor easy to handle and easy to set up.

quick-calibration-groline

Quick Cal for less maintenance.

A single calibration solution for pH and conductivity makes calibration fast and ensures all of your measurements are accurate all of the time for better plant health and better yield.

Features at-a-glance

  • 3 sensors combined in a single rugged probe body: pH electrode with renewable cloth junction, amperometric EC/TDS sensor, and an internal temperature sensor for temperature compensated readings
  • IP65 rated enclosure: designed to withstand harsh grow environments
  • Wide pH Range: measure pH from 0.00 to 14.00 pH
  • Selectable EC to TDS/ppm conversion factor: choice of either a 0.5 or 0.7 conversion factor
  • Automatic Temperature Compensation: all readings are compensated for variations in temperature, temperature displayed in ℃ or ℉ along with pH, EC or TDS reading
  • Large LCD with plant-friendly green backlighting: LCD can display all three essential hydroponic nutrient measurements at one time, a 3-second cycle of single measurements, or a real-time graph screen with options for measurement selection and log recall
  • Data logging for 30 days: logs every 15 minutes for last 30 days, stores min, max, and average values
  • Data transfer: USB-C port for easy data transfer to memory stick or PC
  • High and low alarms: warns when your nutrient solution is out of desired range by flashing display and message
  • Ambient light sensor: for automatic LCD dimming
SKU HI981421-02
Name GroLine Monitor for Hydroponic Nutrients - HI981421-Threaded probe for insertion mounting
pH Range 0.00 to 14.00 pH; 0.0 to 14.0 pH
pH Resolution 0.01 pH; 0.1 pH
pH Accuracy ±0.05 pH; ± 0.1 pH
pH Calibration one or two-point calibration (using pH 4.01,7.01, 10.01 buffers) using auto buffer recognition; one-point calibration using quick calibration solution
pH Temperature Compensation automatic (0.0 to 60.0ºC/ 32.0 to 140.0°)
EC Range 0.00 to 10.00 mS/cm
EC Resolution 0.01 mS/cm
EC Accuracy ±0.1mS/cm (0.00 to 5.00mS/cm); ±0.2mS/cm (5.00 to 10.00mS/cm)
EC Calibration one-point at 1.41 mS/cm or 5.00 mS/cm using auto standard recognition; one-point calibration using quick calibration solution
TDS Range 0 to 5000 ppm (TDS conversion factor 0.5 (500 CF)); 0 to 7000 ppm (TDS conversion factor 0.7 (700 CF))
TDS Resolution 10 ppm
TDS Accuracy ±2% f.s.
EC/TDS Temperature Compensation automatic
Temperature Correction Coefficient β set at 1.9%/°C
EC to TDS Conversion Factor TDS conversion factor 0.5 (500 CF); TDS conversion factor 0.7 (700 CF)
Temperature Range 0.0 to 60.0°C / 32.0 to 140.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C /±1°F
Alarm Relay Set Point high and low with enable/disable option for all parameters
Multi-parameter Probe HI1285-8 pH/EC/TDS/temperature polypropylene body, pre-amplified multiparameter probe with internal temperature sensor DIN connector and 2 m (6.6’) cable
Logging Type automatic logging for last 30 days at 15 minute interval
Connectivity USB Type-C for flash drive or compatible device
GLP last 5 pH and EC calibrations
Display 128 x 64 pixel B/W LCD with green backlight
Power Supply 12VDC adapter (included)
Environment -5 to 50°C (23 to 122°F); RH max 95% non-condensing
IP Rating IP65
Dimensions 125 x 185 x 38 mm (4.92 x 7.28 x 1.49”)
Weight 333g ( 11.7oz.)

HI981420 is supplied with: HI1285-8 multi-parameter probe, HI50036-0 Quick Cal buffer solution sachet (2), HI700661P electrode cleaning solution sachets for agriculture (2), 12VDC adapter, calibration certificates for both meter and probe, and instruction manual.

All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please send an email to sales@hannainst.com.au or call us on (03) 9769 0666.

Free standard delivery: We offer free delivery within Australia on orders over $100, typically arriving within 5 to 7 days. Delivery times may vary depending on the courier service and the recipient's location. Free shipping is not available with other offers or discounts.

Same-day despatch: Place your order before 1 PM Monday to Friday for same-day despatch. Delivery times may vary depending on the courier service and the recipient's location. Subject to stock availability.

Please note that we do not offer shipping to PO Box addresses.

Additional information

Weight 0.49 kg
Parameter

Conductivity/TDS, pH

pH Accuracy

±0.05 pH; ±0.1 pH

pH Calibration

10.01 buffers) using auto buffer recognition; one-point calibration using quick calibration solution, 7.01, one or two-point calibration (using pH 4.01

pH Range

0.00 to 14.00 pH; 0.0 to 14.0 pH

pH Resolution

0.01 pH; 0.1 pH

EC Accuracy

±0.1mS/cm (0.00 to 5.00mS/cm); ±0.2mS/cm (5.00 to 10.00mS/cm)

EC Calibration

one-point at 1.41 mS/cm or 5.00 mS/cm using auto standard recognition; one-point calibration using quick calibration solution

EC Range

0.00 to 10.00 mS/cm

EC Resolution

0.01 mS/cm

TDS Accuracy

±2% f.s.

TDS Range

0 to 5000 ppm (TDS conversion factor 0.5 (500 CF)); 0 to 7000 ppm (TDS conversion factor 0.7 (700 CF))

TDS Resolution

10 ppm

Temperature Accuracy

±0.5°C /±1°F

Temperature Range

0.0 to 60.0°C / 32.0 to 140.0°F