Hydrazine is a liquid chemical substance normally used in high pressure heating plants because of its properties as an oxygen inhibitor, helping to avoid scaling and corrosion in the plant itself. Hydrazine reacts with dissolved oxygen to yield nitrogen and water; this is an advantage over the sulfite treatment because it does not produce any dissolved solids in the boiled water. Hydrazine is also used as an energy source in fuel elements, as a reducing agent for metal recovery, and as an intermediate in the production of insecticides, herbicides, pharmaceuticals, and many other chemical products.
The HI97704 uses an Adaptation of the Standard Methods for the ASTM Manual of Water and Environmental Technology, Method D1385, p-Dimethylaminobenzaldehyde method to measure hydrazine concentrations up to 400 µg/L (ppb). When the reagent is added to samples containing hydrazine, the sample turns a yellow hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For hydrazine determination, a narrow band interference filter at 466 nm allows only blue light to be emitted and passed through the sample cuvette.
This innovative optical system offers superior performance in accuracy, repeatability, and required time to perform a measurement. This compact, waterproof meter has a tutorial mode that walks the user graphically, step by step, to perform a measurement. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use.
- LED that generates very little heat.
- 8 nm narrowband interference filter that is accurate to ±1 nm.
- Reference detector that modulates the voltage to LED for consistent light output.
- A concave focusing lens that reduces errors from imperfections in the cuvette.
On-Screen Features
CAL Check
Advanced features including CAL-Check to verify performance and if necessary, recalibrate.
Setup Options
Setup options for meter personalization include date and time format, language, and enabling the tutorial mode.
Backlit Display
Backlit dot matrix LCD that offers an exceptionally intuitive user interface that is easy to read and understand.
Tutorial Mode
Tutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.
Reaction Timer
Built-in reaction timer that ensures consistency amongst multiple users.
HI97704 FEATURES/BENEFITS:
Stable Light Source:
- The internal reference system of the HI97704 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.
High Efficiency Light Source:
- LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.
High Quality Filters:
- Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.
Greater Light Yield:
- A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.
CAL Check Functionality:
- Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.
Large Cuvette Size:
- The sample cell of the HI97704 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.
Intuitive Dot Matrix Display:
- The HI97704 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.
Auto-off Protection:
- The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.