Hanna Instruments Australia
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm
Hanna Instruments Australia
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm

edge® Multiparameter DO Meter - HI2040

$1,573.34

edge® tablet style meter is a groundbreaking design that is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The smart, slim-line design means edge can be used as a hand held, wall mount or bench top meter. Combined with sophisticated technology, it delivers fast accurate results with laboratory grade precision whichever format you choose to use. Cutting-edge design, capacitive touch keypad and an intuitive user interface are just some of the attributes that make this meter stand out. DO is measured through a unique digital electrode. Connected via an easy plug-in 3.5mm connector, this smart electrode enables edge to automatically recognise and store sensor type, ID and calibration information. Programmed for basic and advanced modes, edge offers simplified screen features for routine measurements or detailed data display. It warns users if the electrode is not clean or if buffers are contaminated during calibration using the exclusive Hanna CAL Check feature

Description

edge® is packed with many cutting edge features to ensure accuracy and usability.

Digital Electrodes

edge electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.

 

Sensor Check

When used with Hanna’s pH electrodes equipped with a matching pin, edge constantly checks the impedance of the pH measuring electrode to notify you in real time in the event of glass breakage. During calibration, Sensor Check checks the state of the junction. The reference junction is also evaluated and reported on the display.

3.5 mm Probe Input

Plugging an electrode in has never been simpler; no alignments, no broken pins, just connect the 3.5 mm plug and get started.

edge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.

Wall Mount

Using the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built-in connector to power edge and charge its batteries. edge’s zero footprint is designed to save you valuable benchtop space.

Cradle and Electrode Holder

edge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimum viewing angle.

edge® is incredibly thin and weighs only 8.8 oz., has an 8 hour battery life, and dual USB inputs.

Two USB Ports

edge includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.

Data Logging

edge allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.

Two Operating Modes

edge can be used in Extended or Basic Operating Modes. Extended Mode enables all features available while the Basic Mode reduces the amount of features to a very simple operation. For example, in extended mode edge offers 5 point calibration with 2 custom buffers while in basic mode calibration can only be performed to 3 points with 5 preprogrammed buffers.

Video

 

SKU HI2040-01
Name ® Multiparameter DO Meter - HI2040
pH Range -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV
pH Resolution 0.001 pH, 0.01 pH, 0.1 mV
pH Accuracy ±0.002 pH, ±0.01 pH, ±0.2 mV
pH Calibration Automatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers*
pH Temperature Compensation ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*
pH CAL Check (electrode diagnostics) glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time
EC Range 0.00 to 29.99 µS/cm, 3.00 to 29.99 µS/cm, 30.0 to 299.9 µS/cm, 300 to 2999 µS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm, absolute conductivity ‡
EC Resolution 0.01 µS/cm, 00.1 µS/cm, 0.01 µS/cm, 0.01 mS/cm, 00.1 mS/cm
EC Accuracy ±1% of reading (±0.05 µS/cm or 1 digit, whichever is greater)
EC Calibration 1 Cell Factor calibration; 6 standards available: 84, 1413 µS/cm, 5.00, 12.88, 80.0, 111.8 mS/cm, 1 point offset: 0.00 µS/cm
TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor)
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
EC/TDS Temperature Compensation Automatic -5 to 100 ºC (23 to 212 ºF); NoTC - can be selected to measure absolute conductivity
Temperature Correction Coefficient 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC
EC to TDS Conversion Factor 0.40 to 0.80 (default value is 0.50)
Salinity (% NaCl) Range 0.0 to 400.0% NaCl *
Salinity (% NaCl) Resolution 0.1% NaCl
Salinity (% NaCl) Accuracy ±1% of reading (@25ºC/77ºF)
Salinity (% NaCl) Calibration 1 point with HI 7037L 100% NaCl sea water standard
Salinity (PSU) Range 2.00 to 42.00 PSU *
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ±1% of reading (@25ºC/77ºF)
Salinity (PSU) Calibration through EC calibration
Salinity Range 0.0 to 80.0 g/L *
Salinity Resolution (ppt) 0.01 g/L
Salinity Accuracy (ppt) ±1% of reading (@25ºC/77ºF)
Salinity Calibration (ppt) through EC calibration
Dissolved Oxygen Range 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation
Dissolved Oxygen Resolution 0.01 ppm, 0.1% saturation
Dissolved Oxygen Accuracy ±1 digit, ±1.5% of reading
Dissolved Oxygen Calibration one or two points at 0% (HI 7040 solution) and 100% (in air)
Dissolved Oxygen Temperature Compensation ATC: 0 to 50 ºC; 32.0 to 122.0 °F
Salinity Compensation 0 to 40 g/L (with 1 g/L resolution)
Altitude Compensation -500 to 4000 m (with 100 m resolution)
Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±1.0 °F
DO Probe HI 764080 (included)
Logging Type Manual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots)
Logging Memory up to 1000*** records
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)

HI2040 includes: HI764080 Dissolved Oxygen electrode, HI7041S refill electrolyte solution, (2) DO membrane caps, (2) DO membrane cap O-rings,USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, instruction manual, and quality certificate.

All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please send an email to sales@hannainst.com.au or call us on (03) 9769 0666.

Free standard delivery: We offer free delivery within Australia on orders over $100, typically arriving within 5 to 7 days. Delivery times may vary depending on the courier service and the recipient's location. Free shipping is not available with other offers or discounts.

Same-day despatch: Place your order before 1 PM Monday to Friday for same-day despatch. Delivery times may vary depending on the courier service and the recipient's location. Subject to stock availability.

Please note that we do not offer shipping to PO Box addresses.

Additional information

Weight 2.62 kg
Parameter

Dissolved, Oxygen

pH Accuracy

±0.002 pH, ±0.01 pH, ±0.2 mV

pH Calibration

10.01, 12.45*) and 2 custom buffers*, 4.01 or 3.00, 5 standard (7 standard*) buffers available (1.68*, 6.86, 7.01, 9.18, automatic, up to 3 points (5 points*) calibration

pH Range

-2.00 to 16.00 pH, -2.000 to 16.000 pH, ±1000 mV

pH Resolution

0.001 pH, 0.01 pH, 0.1 mV

EC Accuracy

±1% of reading (±0.05 µS/cm or 1 digit, whichever is greater)

EC Calibration

1 Cell Factor calibration; 6 standards available: 84, 1 point offset: 0.00 µS/cm, 111.8 mS/cm, 12.88, 1413 µS/cm, 5.00, 80.0

EC Range

0.00 to 29.99 µS/cm, 3.00 to 29.99 mS/cm, 3.00 to 29.99 µS/cm, 30.0 to 200.0 mS/cm, 30.0 to 299.9 µS/cm, 300 to 2999 µS/cm, absolute conductivity ‡, up to 500.0 mS/cm

EC Resolution

0.01 mS/cm, 0.01 µS/cm, 00.1 mS/cm, 00.1 µS/cm

TDS Accuracy

±1% of reading (±0.03 ppm or 1 digit, whichever is greater)

TDS Calibration

through EC calibration

TDS Range

0.00 to 14.99 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), up to 400.0 g/L absolute TDS ‡ (with 0.80 factor)

TDS Resolution

0.01 g/L, 0.01 ppm, 0.1 g/L, 0.1 ppm, 1 ppm

Temperature Accuracy

±0.5 °C, ±1.0 °F

Temperature Range

-20.0 to 120.0 ºC, -4.0 to 248.0 °F