The HI98199 is a rugged, portable multiparameter meter with a single digital probe input. The digital probe input allows the connection of either a pH, conductivity or dissolved oxygen probe. Between the three probes and a built-in barometric pressure transducer the HI98199 can measure up to 10 water quality parameters with 5 being measured by sensors and the other 5 by calculation (i.e. EC to TDS). This professional, waterproof meter complies to IP67 standards and is supplied with all necessary accessories to measure pH/temperature packaged into a durable carrying case.

  • Digital Electrodes
  • USB-C for Data Transfer
  • Dot Matrix Display

 

HI98199

Versatility when you need it.

Hanna’s pH probe – HI829113 is included with the HI98199 and the EC – HI763093 and DO probes – HI764103 can be ordered separately.

 

Click here to buy EC probe – HI763093

Click here to buy DO probe – HI764103

Superior Durability

An IP67-rated, waterproof meter means that this meter is built to withstand immersion in 1m of water for up to 30 minutes. The meter has rubber gaskets sealing the battery compartment and connectors in epoxy to prevent any water from entering and damaging the internal electronics from water. With an ergonomic design and waterproofing the HI98199 will fit well in your hand and provides years of use.

Note: The meter is displayed with an optional shockproof rubber boot for additional protection.

Dot Matrix Display

The large dot matrix display provides for an intuitive user interface in which the user is guided through any setup configuration or calibration. A dedicated help key provides for contextual help that is related to the screen being viewed at the time. The dot matrix display is viewable under bright sunlight and has a backlight for when viewing under poor lighting conditions.

Alphanumeric Keypad

The low profile vulcanized rubber keypad along with virtual keys provide for a quick entry of password, user ID and sample site. The configuration of the meter can be password protected to prevent any unwanted changes. The user and sample ID are stored with any logged readings and can be transferred to a PC for analysis or long term record keeping.

Digital probes for HI98199

Digital Probes

HI98199 uses highly advance digital electrodes featuring a built-in microprocessor that performs the measurements. When these probes are connected to the meter they are automatically detected and the meter is updated to display the appropriate parameter. These digital electrodes also feature a quick connect DIN connector that provides a secure waterproof connection.

Flexibility

HI98199 is supplied with a pH/temperature probe. The meter can always be upgraded to measure dissolved oxygen or conductivity by purchasing the compatible probe.

Traceability

The calibration information for a connected probe can be viewed at anytime using the dedicated Good Laboratory Practice (GLP) button on the meter. The calibration information includes the date, time, calibration points and probe characteristic.

HI98199 USB

Quick Connect Digital Probe Connection with Auto-Sensor Recognition

The Quick Connect DIN connector is designed for quick and secure waterproof connection. The meter will automatically recognizes the probe attached and uploads stored calibration data. Each probe then transmits readings digitally to the meter overcoming challenges faced with standard analog probes.

USB-C Port for Data Transfer

The USB-C port is used for transferring logged data to a PC using Windows compatible software. The HI98199 can log up to 45, 000 samples either by interval logging at a set time period or by log on demand of an individual reading.

Built-in Pressure Transducer

The HI98199 has a built in pressure transducer for the measurement of barometric pressure. The pressure measurement can be viewed with any probe connected but the measurement is used when measuring dissolved oxygen for automatic atmospheric pressure compensation.

SKU HI98199
Name Multiparameter Portable pH/EC/DO Waterproof Meter - HI98199
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration automatic one, two, or three points of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
pH Temperature Compensation yes
mV Range ±600.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.5 mV
EC Range 0 to 200 mS/cm
EC Resolution 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm
EC Accuracy ±1.5% of reading or ±2 µS/cm whichever is greater
EC Calibration automatic single-point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range 0.0 to 200.0 ppt (g/L) (the maximum value depends on the TDS factor)
TDS Resolution 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L)
TDS Accuracy ±1% of reading or ±1 ppm (mg/L) whichever is greater
TDS Calibration based on conductivity calibration
EC/TDS Temperature Compensation yes
Temperature Correction Coefficient 0.00 to 6.00 %/°C
EC to TDS Conversion Factor 0.00 to 1.00
Reference Temperature 25 °C or 20 °C
Cell Type four ring
EC/TDS Multi-range Measurement Modes yes
Salinity (PSU) Range 0.00 to 70.00 PSU
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ±2% of reading or ±0.01 PSU whichever is greater
Salinity (PSU) Calibration based on conductivity calibration
Salinity (Seawater Sigma) Range 0.0 to 50.0 σt, σ0, σ15
Salinity (Seawater Sigma) Resolution 0.1 σt, σ0, σ15
Salinity (Seawater Sigma) Accuracy ±1 σt, σ0, σ15
Salinity (Seawater Sigma) Calibration based on conductivity calibration
Resistivity Range 0 to 999999 Ω cm; 0 to 1000.0 kΩ cm; 0 to 1.0000 MΩ cm
Resistivity Resolution 1 Ω cm; 0.1 kΩ cm; 0.0001 MΩ cm
Resistivity Calibration based on conductivity calibration
Dissolved Oxygen Measurement Type galvanic
Dissolved Oxygen Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
Dissolved Oxygen Resolution 0.1%; 0.01 ppm (mg/L)
Dissolved Oxygen Accuracy 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater
300.0 to 500.0%: ±3% of reading
0.00 to 30.00 ppm (mg/L) ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater
30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading
Dissolved Oxygen Calibration automatic one or two points at 0, 100% or one custom point
Dissolved Oxygen Temperature Compensation yes
Barometric Pressure Compensation yes
Salinity Compensation yes
Temperature Range -5.00 to 55.00 °C; 23.00 to 131.00 °F; 268.15 to 328.15 K
Temperature Resolution 0.01 °C; 0.01 °F; 0.01 K
Temperature Accuracy ±0.15 °C; ±0.27 °F; ±0.15 K
Temperature Calibration automatic at one custom point
Temperature Compensation automatic from -5 to 55 °C (23 to 131 °F)
Logging Type continuous logging or log-on-demand
Logging Memory 45000 records
Logging Interval one second to three hours
Connectivity via USB-C with Hanna software
Automatic Shut-Off Not used (disabled), 5, 10, 15, 20, 30, 60 minutes
GLP yes
Calibration Timeout Reminder yes
Display dot matrix
Battery Type/Life 1.5V AA batteries (4) / approximately 400 hours of continuous use without backlight (50 hours with backlight)
IP Protection IP67
Environment 0 to 50 °C (32 to 122 °F); RH 100%
Dimensions 185.0 x 93.0 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 400 g (14.2 oz.)

HI98199 is supplied with the HI829113 pH digital probe with 4m (13’) cable, pH calibration solution sachets, PC software, micro USB cable, batteries, quality certificate, and instruction manual in a rugged carrying case.

All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please send an email to sales@hannainst.com.au or call us on (03) 9769 0666.

Free standard delivery: We offer free delivery within Australia on orders over $100, typically arriving within 5 to 7 days. Delivery times may vary depending on the courier service and the recipient's location. Free shipping is not available with other offers or discounts.

Same-day despatch: Place your order before 1 PM Monday to Friday for same-day despatch (leaves our warehouse). Delivery times may vary depending on the courier service and the recipient's location. Subject to stock availability.

Please note that we do not offer shipping to PO Box addresses.

Additional information

Weight 2.7 kg
Parameter

Conductivity/TDS, Dissolved, Oxygen, pH, Resistivity, Salinity, Temperature

pH Accuracy

±0.02 pH

pH Calibration

10.01) or one custom buffer, 6.86, 7.01, 9.18, automatic one, or three points of five standard buffers (pH 4.01, two

pH Range

0.00 to 14.00 pH

pH Resolution

0.01 pH

EC Accuracy

±1.5% of reading or ±2 µS/cm whichever is greater

EC Calibration

111.8 mS/cm) or custom point, 12.88 mS/cm, 1413 µS/cm, 5.00 mS/cm, 80.0 mS/cm, automatic single-point, with six standard solutions (84 µS/cm

EC Range

0 to 200 mS/cm

EC Resolution

1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm

TDS Accuracy

±1% of reading or ±1 ppm (mg/L) whichever is greater

TDS Calibration

based on conductivity calibration

TDS Range

0.0 to 200.0 ppt (g/L) (the maximum value depends on the TDS factor)

TDS Resolution

1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L)

Temperature Accuracy

±0.15 °C; ±0.27 °F; ±0.15 K

Temperature Range

-5.00 to 55.00 °C; 23.00 to 131.00 °F; 268.15 to 328.15 K