Hanna Instruments Australia
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm
Hanna Instruments Australia
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm

pH Analog Controller with Dual Output and Self-Diagnostic Test – HI8711

$1,417.14


All prices include GST and not all items are stock items.

HI8711 allows the selection of two set points with two independent outputs for acid and alkaline dosages.

  • Auto-diagnostics to verify offset, slope calibration, and electrode contamination/deterioration
  • Hanna’s exclusive Fail Safe Alarm System protects against risks typical of industrial environments
  • Selectable manual ON, OFF and automatic dosing control for alkaline and acid dosing with indicator
  • 0.2 to 3.00 pH alarm tolerance range

Description

Fail Safe Alarm System

Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.

Overtime Dosing Protection

The HI8711 incorporates adjustable overtime dosing protection from 5 to 60 minutes. If dosing exceeds selected time, the alarm will be triggered and the dosing contact will deactivate. This feature can be activated or deactivated.

Output and Input Connections

Each model accepts either a direct input from a pH or ORP electrode or from a transmitter through 4-20 mA input. The instrument also provides ±5V power output and input terminals for amplified electrodes. Moreover, you can choose the output configuration for connecting a recorder or a PLC, between 0-20 or 4-20 mA.

Self-Diagnostic Test

Built-in autodiagnostic functions enable the user to check and troubleshoot any malfunctions. The functions are made via front panel keys to isolate the cause of malfunction whether it is due to pH electrode contamination, internal offset circuit or the amplifier circuit.

Matching Pin Connection

Supports potential matching pin connection to avoid typical problems caused by grounding loop currents, such as progressive damage of the electrode, fluctuating measurements, and poor process regulation.

Robust Design

A removable, transparent splash-proof cover protects the front panel.

SKU HI8711
Name pH Analog Controller with Dual Output and Self-Diagnostic Test – HI8711
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH (0 to 100 °C)/ ±0.05 pH (-20 to 0 °C) (electrode); ±0.5% (transmitter)
pH Dosing Relay 2, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected)
pH Dosing Set Point 0.00 to 14.00 pH
Dosing Control OFF/AUTO/ON with selection switch
Over Dosing Control Adjustable, from 5 min to 60 min with knob or Disable by wire strap - on rear panel
Analog Input Signal 4 to 20 mA
Analog Ouput Signal 0-20 mA or 4-20 mA (isolated)
Backlight Continuous ON
Voltage Output ±5 Vcc; 150 mA max load for amplified electrodes
Enclosure Black anodized aluminium body; front and back with ABS; transparent splash-proof front cover
Power Supply 115 or 230 Vac; 60/50 Hz
Environment -10 to 50°C (14 to 122°F); RH max 95% non-condensing
Dimensions 141 x 69 mm (5.6 x 2.7'')
Weight 1 kg (2.2 lb.)

All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please send an email to sales@hannainst.com.au or call us on (03) 9769 0666.

Free standard delivery: We offer free delivery within Australia on orders over $100, typically arriving within 5 to 7 days. Delivery times may vary depending on the courier service and the recipient's location. Free shipping is not available with other offers or discounts.

Same-day despatch: Place your order before 1 PM Monday to Friday for same-day despatch. Delivery times may vary depending on the courier service and the recipient's location. Subject to stock availability.

Please note that we do not offer shipping to PO Box addresses.

Additional information

Weight 0.45 kg
Parameter

pH

pH Accuracy

±0.02 pH (0 to 100 °C)/ ±0.05 pH (-20 to 0 °C) (electrode); ±0.5% (transmitter)