pH Analog Controller with Self-Diagnostic Test – HI8710

$1,331.11


All prices include GST and not all items are stock items.

HI8710 is a panel mounted pH controller with self-diagnostic test capabilities. Users can set: the setpoint for acid or alkaline dosage, the tolerance of the setpoint before an alarm is activated, the dosage mode: automatic, continuous on or OFF and the over dosage control by setting the overtime dosage knob.

  • Hanna’s exclusive Fail Safe Alarm System protects against risks typical of industrial environments
  • Temperature compensation ensures fast, accurately compensated readings
  • Backlit, LCD display for easy viewing

Description

Fail Safe Alarm System

Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.

Overtime Dosage

“Overtime dosage” function with selection knob and jumper for disable on the rear panel. If the dosing relay remains continuously activated for more than selected dosing time the alarm relay is activated, the alarm LED is blinking and the dosing relay is deactivated.

ORP Dosing Consent Device

When used in conjunction with the HI8720 ORP controller, the ORP Dosing Consent Device function will ensure that the ORP dosage will start only when the pH level is correct.

Automatic Temperature Compensation

A 2-wire Pt100 can be connected to provide automatic temperature compensation of the pH measurements.

Matching Pin Connection

Supports potential matching pin connection to avoid typical problems caused by grounding loop current, such as progressive damage of the electrode, fluctuating measurements, and poor process regulation.

Robust Design

A removable, transparent splash-proof cover protects the front panel.

SKU HI8710
Name pH Analog Controller with Self-Diagnostic Test – HI8710
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH (0 to 100 °C)/ ±0.05 pH (-20 to 0 °C) (electrode); ±0.5% (transmitter)
pH Calibration Offset: ±2 pH with OFFSET trimmer; Slope: 80 to 110% with SLOPE trimmer
pH Temperature Compensation Fixed or automatic with Pt100 from -20 to 100 °C (-4 to 212 °F)
Alarm Relay Set Point 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected)
Alarm Relay Range 0.2 to 3.00 pH
Analog Input Signal 4 to 20 mA
Analog Ouput Signal 0-20 mA or 4-20 mA (isolated)
Backlight Continuous ON
Voltage Output ±5 Vcc; 150 mA max load for amplified electrodes
Enclosure Black anodized aluminium body; front and back with ABS; transparent splash-proof front cover
Environment -10 to 50°C (14 to 122°F); RH max 95% non-condensing
Dimensions 141 x 69 mm (5.6 x 2.7'')
Weight 1 kg (2.2 lb.)

All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please send an email to sales@hannainst.com.au or call us on (03) 9769 0666.

Free standard delivery: We offer free delivery within Australia on orders over $100, typically arriving within 5 to 7 days. Delivery times may vary depending on the courier service and the recipient's location. Free shipping is not available with other offers or discounts.

Same-day despatch: Place your order before 1 PM Monday to Friday for same-day despatch. Delivery times may vary depending on the courier service and the recipient's location. Subject to stock availability.

Please note that we do not offer shipping to PO Box addresses.

Additional information

Weight 0.45 kg
Parameter

pH

pH Accuracy

±0.02 pH (0 to 100 °C)/ ±0.05 pH (-20 to 0 °C) (electrode); ±0.5% (transmitter)

pH Calibration

Offset: ±2 pH with OFFSET trimmer; Slope: 80 to 110% with SLOPE trimmer

pH Range

0.00 to 14.00 pH

pH Resolution

0.01 pH