Pump Calibration Standard for Titratable Acidity in Dairy Mini Titrator, 230 mL bottle - HI84529-55

Original price was: $68.18.Current price is: $57.95.


Prices include GST. Not all items are in stock. Call 03 9769 0666 to confirm.

The HI84529-55 is a 230 mL pump calibration standard made for use with the HI84529 Titratable Acidity Mini Titrator in dairy testing. It helps calibrate the dosing system so the titrant is delivered accurately during each analysis. This is important because the instrument relies on the exact volume dispensed, along with the titrant concentration, to calculate titratable acidity.

It’s best to carry out a calibration whenever the titrant or pH electrode has been replaced, and to do it regularly to keep results consistent and reliable.

The solution comes pre-measured and ready to use, with a clearly marked batch number and expiry date. It is supplied in a tightly sealed bottle with a tamper-evident cap to maintain quality.

The HI84529-55 is a 230 mL pump calibration standard designed for use with the HI84529 Mini Titrator when measuring acidity in dairy products across both low and high ranges. The number of calibrations required will depend on the range selected for testing.

Acidity in dairy is determined through a neutralisation reaction, where naturally occurring acids are neutralised by a base. In the United States, results are typically reported as a percentage of lactic acid (% l.a.), while other units such as °SH, °D and °Th may also be used.

Using the HI84529 Mini Titrator simplifies titratable acidity testing, combining straightforward sample preparation with an accurate dosing pump, a potentiometric endpoint detection system and automatic result calculations. Since the titrant is pre-standardised, it’s essential to calibrate the dosing pump to confirm the exact volume being delivered. This is done by titrating a known volume of calibration solution to a fixed pH endpoint, measured using the FC260B pH electrode and HI5315 reference electrode.

The HI84529-55 calibration solution is suitable for both low and high range measurements, with the volume used depending on the selected range. Typically, 1 mL is used for the Low Range 20, 2 mL for the Low Range 50, and 10 mL for the High Range 20.

For best results, a pump calibration should be carried out whenever key components such as the titrant, syringe, tubing or pH electrode are replaced. Regular calibration before starting a new series of tests is also recommended to maintain accuracy and consistency.

Replacement reagents required to operate the HI84532 include:

Parameter Low Range 20 (LR 20) Low Range 50 (LR 50) High Range 20 (HR 20)
Range (% l.a.) 0.01 to 0.20 0.01 to 0.20 0.1 to 2.0
Pump Calibration Standard HI84529-55 HI84529-55 HI84529-55
Titrant Solution HI84529-50 HI84529-52 HI84529-51

Purchase & Shipping

All prices are inclusive of GST and not all items are stock items, if you require an immediate solution, please send an email to sales@hannainst.com.au or call us on (03) 9769 0666.

Free standard delivery: Free shipping applies to online orders over $150 placed via our website within Australia, typically arriving within 5 to 7 days. Delivery times may vary depending on the courier service and the recipient’s location. Free shipping is not available with other offers or discounts.

Same-day dispatch: Place your order before 1 PM Monday to Friday for same-day despatch (leaves our warehouse). Delivery times may vary depending on the courier service and the recipient’s location. Subject to stock availability.

Please note that we do not offer shipping to PO Box addresses.