PVDF Body Foodcare pH Electrode with Quick Connect DIN Connector for Dairy Products - FC1013

$379.05

The FC1013 is a PVDF body, refillable, double junction pH electrode with a quick connect connector. This single ceramic, double junction electrode has a pH indicating probe made of general purpose glass and a food grade plastic body.

This design consideration is ideal for pH measurements in the food industry including sauces, juices, dairy products and other liquid or slurry forms of food. The recommended operating temperature range is from 0 to 80℃.

  • Durable PVDF Body
  • Double Junction Design
  • Refillable Electrode

Description

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The FC1013 uses general purpose (GP) glass, spherical bulb, food grade PVDF body, single ceramic frit, double junction and is refillable with 3.5M KCl.

high temperature glass

 

General Purpose Glass Formulation

General Purpose (GP) glass, as the name implies, is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25℃ and is suited for measuring pH of samples that are at ambient temperatures. The FC1013 is suitable to use with samples that measure from 0 to 80℃.

high temperature glass

 

Spherical Bulb

The spherical bulb is for general purpose use within the food industry. Measurements can be made in liquids or slurries that allow easy measurement of solid and semi-solid food products. Other tip shapes include conic for penetration and flat tip for surface measurements.

pvdf body

 

PVDF Body

Polyvinylidene fluoride (PVDF) is a food grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth.

double junction reference

Single Ceramic Double Junction Reference

The FC1013 is a double junction design. pH electrodes are available as single junction or double junction. See below for a complete description of the differences. The junction also known as a salt bridge is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL/hour. Other junction types are available with higher flow rates and made with different materials.

refillable

Refillable

The FC1013 is a refillable probe. Since it is a double junction pH electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode. The absence of silver will prevent any silver precipitate from forming at the junction surface and clogging it. Clogging of the junction will result in drifty and erratic readings.

din connector

 

DIN Connector

The FC1013 uses a quick connect DIN connector. This type of connector isspecific to Hanna pH meters. Other type of connectors include BNC, screw type, T-type, and 3.5mm to name a few.

Single Junction Versus Double Junction pH Electrodes

junction types

Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate forming to clog the junction.

SKU FC1013
Name PVDF Body Foodcare pH Electrode with Quick Connect DIN Connector for Dairy Products - FC1013
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 µL/h
Refill Electrolyte 3.5M KCl
Body Material PVDF
Glass Type general purpose (GP)
Tip / Shape spheric (dia: 7.5 mm)
Matching Pin no
Max. Pressure 0.1 bar
Optimum pH Range pH: 0 to 13
Temperature Operating Range 0 to 80°C (32 to 176°F)
Body Length/Overall Length 120 mm / 160 mm
Temperature Sensor yes
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type quick connect DIN connector
Amplifier yes
Recommended Use dairy, juice, liquids and slurries measurement in food industry, sauces

All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please send an email to sales@hannainst.com.au or call us on (03) 9769 0666.

Free standard delivery: We offer free delivery within Australia on orders over $100, typically arriving within 5 to 7 days. Delivery times may vary depending on the courier service and the recipient's location. Free shipping is not available with other offers or discounts.

Same-day despatch: Place your order before 1 PM Monday to Friday for same-day despatch. Delivery times may vary depending on the courier service and the recipient's location. Subject to stock availability.

Please note that we do not offer shipping to PO Box addresses.

Additional information

Weight 0.16 kg
Parameter

pH