Hanna Instruments Australia
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm
Hanna Instruments Australia
Sales: (03) 9769 0666   |    Mon to Fri: 8:30am – 5:00pm

T-Logger Temperature Data Logger - HI144-kit

$255.81


Prices include GST. Not all items are in stock. Call 03 9769 0666 to confirm.

The HI144 is a waterproof, temperature data logger that can be programmed to log data from 1 minute to 24 hours interval by using the docking cradle and PC software. Other programming options include high and low alarms and a choice of how the data logging starts. The HI144-10 includes the USB cradle and PC software while the HI144 is for the data logger only.

  • Stores up to 8, 000 measurements
  • 2-year battery life
  • Programmable high and low alarms

The monitoring of environmental temperature is very important for many different applications. For cold food storage it is necessary to ensure that the product is always stored properly to maintain quality and for safety to prevent bacteria growth. The monitoring of temperature is critical through all stages in food distribution. This includes from the time it is packaged and stored to transportation to the local market or restaurant. The HI144-10 will help to be compliant in recording temperatures as part of a HACCP monitoring program.

For building maintenance these loggers can track the environmental temperatures of an office or warehouse to ensure that heating or air conditioning thermostats are programmed correctly and that the hot or cold air is distributed evenly.

Using the supplied PC software HI144-10 can be programmed to record the temperature in intervals from 1 minute to 24-hour can store up to 8, 000 readings. The reading can be reviewed on a PC in both table and graphical formats. The graphing function allows the readings to be scaled for increased resolution and, if programmed, to see them in relation to the low and high alarms.

All of the programming is done through a USB docking cradle and PC software. The PC software offers graphical user interface for customizing the settings of the data logger. Once programmed the data logger can be set to start by using the PC, at a specific date/time, by push button start on the logger itself.

The HI144-10 is supplied with the HI144T-Logger, USB cradle, wall mount with lock and software. At a reduced cost, additional HI144 T-loggers can be ordered without the cradle and software. Each T-logger has its’ own unique serial number to identify individual units.

METER FEATURES/BENEFITS:

Compact waterproof data logger

  • LCD displays temperature, high and low alarms, logging status and battery indicator
  • Wall mount with lock
  • USB docking cradle for programming and transferring of data

 

Programming options

  • Choice of start: From the PC, a specific date/time, or push button on T-Logger
  • Choice of measurement units: ℃ or ℉ to display on LCD
  • High and low alarm set points with indicators on LCD
  • Selectable logging interval in minutes and hours
  • Choice of data management: Store until full, fixed number or wrap around

 

Instrument status review

  • Battery life and days used
  • Serial number of device
  • Programmed device settings

 

PC software

  • Graphic user interface to program settings
  • Data export as an .xls file
  • Built in graphing that can be scaled with quick reference to programmed high and low alarm

 

Supplied Complete

  • The HI144-10 is supplied with the HI144 T-Logger, USB cradle, wall mount with lock and software. Additional HI144 T-loggers can be ordered separately.

Specifications

SKU HI144-10
Name T-Logger Temperature Data Logger - HI144-kit
Thermistor Temperature Range -30.0 to 70.0 °C (-22.0 to 158.0 °F)
Thermistor Temperature Resolution 0.1°C (0.1°F)
Thermistor Temperature Accuracy ±0.4°C (-20 to 60°C); ±0.6°C (outside)
±0.7°F (-4 to 140°F); ±1.1°F (outside)
Logging Type interval
Logging Memory up to 8000 samples
Logging Interval user selectable from 1 minute to 24 hours
Connectivity HI144002 docking cradle connected to PC with USB cable and running HI92144 software
Battery Type/Life 1 x CR2032 3V lithium battery / 2 years
Environment 0 to 50°C (32 to 122°F); RH 100% (IP65)
Dimensions 60 x 37 x 17 mm (2.4 x 1.5 x 0.7”)
Weight 29.4 g (1 oz.) with battery

Manuals

Ordering info

HI144-10 is supplied with HI144 T-Logger, HI144002 USB communication cradle, USB flash drive with HI92144 Windows® compatible software, CR2032 lithium ion battery, wall cradle, lock, and instruction manual.

Purchase & Shipping

All prices are inclusive of GST and not all items are stock items, if you require an immediate solution please send an email to sales@hannainst.com.au or call us on (03) 9769 0666.

Free standard delivery: We offer free delivery within Australia on orders over $150, typically arriving within 5 to 7 days. Delivery times may vary depending on the courier service and the recipient's location. Free shipping is not available with other offers or discounts.

Same-day despatch: Place your order before 1 PM Monday to Friday for same-day despatch (leaves our warehouse). Delivery times may vary depending on the courier service and the recipient's location. Subject to stock availability.

Please note that we do not offer shipping to PO Box addresses.

Additional information

Weight 0.23 kg
Parameter

Temperature